Physical Disk Locations (DS4243)
Updated 2024/02/28
Each cell contains the serial number for the drive in the mapped bay.
X1 | X2 | X3 | X4 | |
---|---|---|---|---|
Y1 | VJGPS30X | VK0ZD6ZY | VKH22XPX | VJG2PVRX |
Y2 | VJGR6TNX | 2EG14YNJ | VJGJVTZX | VJG1H9UX |
Y3 | VJGJUWNX | 2EGXD27V | VJGJAS1X | VJG2UTUX |
Y4 | VJGRGD2X | 2EGL8AVV | 2EKA903X | VJGRRG9X |
Y5 | VJGK56KX | 2EGNPVWV | 2EKATR2X | VKH3Y3XX |
Y6 | VLKV9N8V | R5G4W2VV | VLKXPS1V | VKGW5YGX |
Identify a Failing Disk
Disk Smart test errors are reported by device ID (e.g. /dev/sdw), rather than the serial number. To find the serial number associated with a particular device ID, run the following one-liner with $dev
substituted for the device to find:
TODO
Get Serial Number from part-uuid
ls -l /dev/disk/by-partuuid
Will return lines for each partition device and its mapping to a /dev/sd
Linux block device.
From there, run smartctl -a <block device> | grep Serial
where <block device>
is like /dev/sdw
.
Or, as a one-liner with $DISK_UUID
set to the UUID to find:
ls -l /dev/disk/by-partuuid | grep $DISK_UUID | cut -d' ' -f 11 | xargs basename | sed 's/^/\/dev\//' | xargs sudo smartctl -a | grep Serial | tr -s ' ' | cut -d' ' -f 3
It might be possible to pull the part UUID from the zpool status
command directly. An exercise for the reader.
Offline and wipe the failing disk
- Match the disk name (e.g.
/dev/sdw
) to the UUID (e.g.13846695584571018356
). Uselsblk --fs
for this. - Offline the disk:
zpool offline $pool $disk_id
- Wipe the disk:
wipefs $disklabel
(where$disklabel
is like/dev/sdw
) - Run
lsblk --fs
again to verify the wipe worked. If not, you'll need to run a full dd wipe withdd if=/dev/zero of=$disklabel bs=1M
. This will take a long time as it writes zeroes across the entire drive. - Physically remove the disk.
Replace Disk in Pool
Once the failed disk has been identified and physically replaced, you should know the old drive's UUID (via zpool status
) and the new drive's device name (via lsblk
and deduction)
Once the new drive is in place and you know its ID (e.g. /dev/sdw
), run the following to begin the resilver process:
zpool replace <pool> <part-uuid to be replace> <device id of new drive>
E.g. zpool replace Media d50abb30-81fd-49c6-b22e-43fcee2022fe /dev/sdx
This will begin a new resilver operation. Good luck!
https://docs.oracle.com/cd/E19253-01/819-5461/gazgd/index.html
Update Log
Most recent first
- 2024/04/16: Replaced VJG1H9UX with 2EKA92XX at Y2/X4
- 2024/04/07: Replaced VJG282NX with VKH22XPX at Y1/X3
- 2024/03/12: Replaced VLKXPS1V with VKH40L6X at Y6/X3
- 2024/02/28: Replaced 2EKA92XX with VLKXPS1V at Y6/X3
- 2024/02/27: Replaced VJG2T4YX with VJG282NX at Y2/X3